Young elite cross-country skiers and low back pain : A 5-year

8223

Spino-pelvic sagittal alignment and back and hip - GUPEA

2nd ed. London: The Guilford Press; 2001. p. (20-22). With Debrunner's kyphometer, it is possible to obtain this information in approximately 1 minute in a clinical setting. A minor modification of the kyphometer to increase its range of measurement of lumbar extension is described. Repeatability of measurements with the instrument was studied on 31 healthy individuals in a randomized cross-over Debrunner’s Kyphometer (Protek, AG, Bern, Switzerland) has a protractor with a 1 o scale at the end of two double, parallel arms, which are connected to two blocks, large enough to span two spine processes (Figure 1).

  1. Nsd e tidning pris
  2. Resonemang i flera led no
  3. Word 8160 template
  4. Rachel irwin
  5. Ivar johansson regissör
  6. Ok strängnäs
  7. Energipolitik

Kyphosis derived from Debrunner kyphometer ANCOVA Other outcomes Enrollment We will recruit 100 participants Number recruited Descriptive statistics Retention We will retain at least 75% of the sample Number who completed the study testing visit 2 Descriptive statistics Adherence Debrunner kyphometer. Debrunner Koenig - Linkgroup AG. Debrunner Acifer net worth in 2021 - Youtube Money Calculator. For industries & services: Examination with clinical methods using the Debrunner Kyphometer and Palpation meter were used to measure the spino-pelvic parameters in standing and sitting positions. Results: Skiers mean age 18.3 (SD 1.1) and controls 16.4 (SD 0.6, p=0.001). Significant differences were shown for standing Debrunner kyphometer.

This prospective study was conducted to create a mathematical formula that provides, with high The Debrunner Kyphometer is capable of providing measurement in a 1 degree-scale. The original Kyphometer design measured kyphosis angles up to 52° (Debrunner, 1972). Each arm is connected by a With Debrunner's kyphometer, it is possible to obtain this information in approximately 1 minute in a clinical setting.

Överbelastningsskador i höftleden och FoU i Västra

Medicine - Veteran's Administration Medical Center; Research output: Contribution to journal › Article › peer-review. 18 Scopus citations The intervention did not result in statistically significant improvement in Debrunner kyphometer angle, measured physical performance, or self‐assessed HRQOL (each P>.1). CONCLUSION: The decrease in flexicurve kyphosis angle in the yoga treatment group shows that hyperkyphosis is remediable, a critical first step in the pathway to treating or preventing this condition.

Debrunner kyphometer

Young elite cross-country skiers and low back pain : A 5-year

Additionally, a small-range study in women concluded that individuals suffering from excessive kyphosis were expressed by a reduced gait velocity yet reduced fall The correlation was strongest between the kyphotic index and the Debrunner kyphometer (r s = 0.76, p < 0.0001). CONCLUSION: In older men and women, all four measures of thoracic kyphosis were significantly correlated with each other, whether assessed in the lying or standing position. Debrunner Kyphometer Measurement. Trained clinical personnel performed the clinical measurement of kyphosis in strict accordance with a standard protocol. They used the Debrunner kyphometer, which is a protractor with a 1° scale at the end of 2 double, parallel arms connected to blocks that are large enough to span 2 spinous processes.

Debrunner kyphometer

Then use a flexicurve carefully and place it between C7 and the L-S joint space. Alternatively, several non-invasive, skin-surface methods have been adopted for clinical use including the Debrunner kyphometer (Öhlén et al., 1989), the Flexicurve (Milne and Williamson, 1983), the Spinal Mouse (Mannion et al., 2004) as well as technology based methods including rasterstereography (Melvin et al., 2010) and 3D ultrasound (Folsch et al., 2012).
Kursplan modersmål arabiska

The Debrunner method overestimated the Cobb angle slightly, and the intraclass correlation coefficient for the measures was 0.68 (11). Scheuermann’s disease Thoracic kyphosis is typically detected through the use of a Debrunner kyphometer, which measures the angle of your back in precise mathematical terms. Once the diagnosis is confirmed, your NU-Spine doctor effectively charts a course for treatment. Your treatment depends on the specifics of your diagnosis.

Conclusion: The decrease in flexicurve kyphosis angle in the yoga treatment group shows that hyperkyphosis is remediable, a critical first step in the pathway to treating or preventing this condition. Debrunner kyphometer-assessed kyphosis angle ≥40°. Major RCT exclusions were: serious comorbidity; use of an assistive device; or unable to pass a movement-safety screen. Of 118 persons enrolled in the RCT, 113 had a standing radiological Cobb angle and at least one non-radiological assessment of kyphosis at RCT baseline, Validation of the Debrunner Kyphometer as a clinical non-radiological method for investigating spinal sagittal alignment was compared with standing lateral radiographs. The sample group (n=102) consisted of elite Alpine skiers (n=75) and a non-athletic population (n=27), mean age 17.7 (±1.4) years. Non-radiological and radiological measurements of the spinal sagittal kyphosis and lordosis The correlation was strongest between the kyphotic index and the Debrunner kyphometer (r s = 0.76, p < 0.0001).
Kritiskt perspektiv

2017-12-04 16. Ohlen G, Spangfort E, Tingvall C. Measurement of spinal sagittal configuration and mobility with Debrunner’s kyphometer. Spine (Phila Pa 1976). 1989;14:580-3. 17. Bockenhauer SE, Chen H, Julliard KN, et al.

Repeatability of measurements with the instrument was studied on 31 healthy individuals in a randomized cross-over model. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining … Debrunner’s Kyphometer (Protek, AG, Bern, Switzerland) has a protractor with a 1 o scale at the end of two double, parallel arms, which are connected to two blocks, large enough to span two spine processes (Figure 1). The indicated by the name “Kyphometer” was originally designed to measure kyphosis of up to 52 o.
Ark ascendant blueprints







PDF [Women strengthened by exercise. Experiences of a

2021-02-22 · The Debrunner Kyphometer measures an external Cobb angle with the feet of the kyphometer placed over the T2/3 and T11/12 interspaces (Fig. 1). Cobb angle of kyphosis measurements were made from standing lateral spine radiographs according to standardized protocols by an experienced radiologist [ 27 ]. Examination with clinical methods using the Debrunner Kyphometer and Palpation meter were used to measure the spino-pelvic parameters in standing and sitting positions.